Vai al contenuto

AF16Z-30-01K-30 24VDC Contactor

Link copied
SKU
EAN
GTIN
MPN
AF16Z..K 3-pole contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF16Z..K contactors with coil 30 include a 24 V DC electronic coil interface with a built-in surge suppression, obtaining a reduced holding coil consumption up to 1.7 W for a low panel energy consumption and a direct control by PLC-output ≥ 250 mA 24 V DC, without need of additional interface relay.Only AF..Z..-30 contactors need to respect the polarity on the coil terminals (A1+ and A2-). AF16Z..K include Push-in Spring terminals. Only one push is all you need for extremely fast wiring: faster than ever installation, easier than ever wiring, reliable as ever connections. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks. (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Accessories: a wide range of accessories is available.

Specifiche tecniche

Altezza 92.3 mm
Larghezza 45 mm
Profondità 97 mm
Tensione d'esercizio in DC 690 - 690 V
Adatto per installazione in serie no
Potenza di esercizio nominale NEMA -
Tipo di tensione per l'azionamento DC
Numero di contatti ausiliari, normalmente aperto 0
Tensione di alimentazione pilota nominale per DC 24 - 24 V
Numero di contatti principali, normalmente chiusi 0
Potenza d'esercizio nominale per DC-3 / DC-5 a 440 V -
Tensione di alimentazione pilota nominale per AC 60 hz

Prodotti correlati

AF30-30-00-13 bob. 100...250 V c.a./c.c.
ABB

AF30300013

AF30-30-00-13 bob. 100...250 V c.a./c.c.

Codice Ordine: AF30300013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-15 kW (AC-3...

AF38-30-00-11 bob. 24...60 V c.a./c.c.
ABB

AF38300011

AF38-30-00-11 bob. 24...60 V c.a./c.c.

Codice Ordine: AF38300011 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-18,5 kW (AC-3...

AF38-30-00-13 bob. 100...250 V c.a./c.c.
ABB

AF38300013

AF38-30-00-13 bob. 100...250 V c.a./c.c.

Codice Ordine: AF38300013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-18,5 kW (AC-3...

AF09Z-40-00-21 bob. 24...60 V c.a./c.c.
ABB

AF09Z400021

AF09Z-40-00-21 bob. 24...60 V c.a./c.c.

Codice Ordine: AF09Z400021 - Contattori fino a 100A-Contattori quadripolari AF09…AF38 a basso assorbimento-Poli 4 NA...

AF16-30-10-11 bob. 24...60 V c.a./c.c., aux 1NA
ABB

AF16301011

AF16-30-10-11 bob. 24...60 V c.a./c.c., aux 1NA

Codice Ordine: AF16301011 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-7,5 kW...

AF16-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA
ABB

AF16301013

AF16-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA

Codice Ordine: AF16301013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-7,5 kW...