The NF31EK-13 is a 690 V IEC or 600 UL 4-pole contactor relay with Push-in Spring terminals, used for switching auxiliary and control circuits. Only one push is all you need for extremely fast wiring: faster than ever installation, easier than ever wiring, reliable as ever connections. Thanks to the AF technology, the contactor relay has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. NF contactor relays have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. These contactor relays include mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and are side-marked with the "Mechanically Linked" symbol.

Specifiche tecniche

Altezza 92.3 mm
Larghezza 45 mm
Interfaccia no
Profondità 77 mm
Comando manuale no
Tipo di montaggio Barra DIN/vite
Con indicatore a LED no
Tensione d'esercizio in DC 6 - 6 V
Corrente d'esercizio nominale 3 A
Tensione d'esercizio in AC 60 Hz 690 - 690 V
Tipo di tensione per l'azionamento AC/DC
Numero di contatti ausiliari, di scambio 0
Numero di contatti ausiliari, normalmente chiusi 1
Tipo di collegamento circuito elettrico ausiliario Connessione a spine
Tensione di alimentazione pilota nominale per AC 60 hz 100 - 250 V
Numero di contatti ausiliari, contatti di chiusura, a commutazione anticipata 0

Prodotti correlati

AF09-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA
ABB

AF09301013

AF09-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA

Codice Ordine: AF09301013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-4 kW (AC-3...

AF12-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA
ABB

AF12301013

AF12-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA

Codice Ordine: AF12301013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-5,5 kW...

AF16-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA
ABB

AF16301013

AF16-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA

Codice Ordine: AF16301013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-7,5 kW...

AF116-40-11-13 bob. 100...250 V c.a./c.c.
ABB

AF116401113

AF116-40-11-13 bob. 100...250 V c.a./c.c.

Codice Ordine: AF116401113 - Contattori oltre 100A-Contattori quadripolari AF09…AF370 e EK550..EK1000-160 A (AC-1 690 V)

AF26-30-00-13 bob. 100...250 V c.a./c.c.
ABB

AF26300013

AF26-30-00-13 bob. 100...250 V c.a./c.c.

Codice Ordine: AF26300013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-11 kW (AC-3...

AF30-30-00-13 bob. 100...250 V c.a./c.c.
ABB

AF30300013

AF30-30-00-13 bob. 100...250 V c.a./c.c.

Codice Ordine: AF30300013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-15 kW (AC-3...