The softstarter PSR6-600-11 has a rated maximum operational current of 6 A with an operating voltage span from 208...600 V AC. The rated control voltage is 24 V AC/DC. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.

Specifiche tecniche

Funzione -
Con display no
Classe di intervento Regolabile
Cavallottamento interno si
Grado di protezione (IP) IP20
Regolazione della coppia no
Grado di protezione (NEMA) 1
Tensione d'esercizio nominale Ue 208 - 600 V
Corrente d'esercizio nominale Ie a 40°C Tu 6.8 A
Tensione di alimentazione pilota nominale per DC 24 - 24 V
Tensione di alimentazione pilota nominale per AC 50 hz 24 - 24 V
Potenza nominale motore trifase, circuito standard, a 230 V 1.5 kW
Potenza nominale motore trifase, circuito a radice di 3, a 230 V -

Documenti

Deeplink REACH

2CMT2022-006481_en_D_REACh Declaration for all Softstarters.pdf

Apri

Instructions for use

1SFC132076M9901,A.pdf

Apri

Declaration RoHS

2CMT2022-006500_en_C_RoHS II Declaration for all Softstarters.pdf

Apri

Prodotti correlati

Minicontattori VB6A 220 ... 240 V AC - 3 NO - 0 NC - Screw Terminals
ABB

EL 473 5

Minicontattori VB6A 220 ... 240 V AC - 3 NO - 0 NC - Screw Terminals

Codice Ordine: EL 473 5 - Minicontattori-Minicontattori invertitori tripolari con connessione a vite-4 kW (AC-3), bobina...

AA1-230 Con alimentazione 200-240 V 50/60 Hz
ABB

EP 697 5

AA1-230 Con alimentazione 200-240 V 50/60 Hz

Codice Ordine: EP 697 5 - Salvamotori e relè termici-MS116, Mx132, MS132T e Mx165 - Accessori-Bobine di sgancio a lancio...

AF09-30-10-11 bob. 24...60 V c.a./c.c., aux 1NA
ABB

AF09301011

AF09-30-10-11 bob. 24...60 V c.a./c.c., aux 1NA

Codice Ordine: AF09301011 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-4 kW (AC-3...

AF09-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA
ABB

AF09301013

AF09-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA

Codice Ordine: AF09301013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-4 kW (AC-3...

AF09Z-40-00-21 bob. 24...60 V c.a./c.c.
ABB

AF09Z400021

AF09Z-40-00-21 bob. 24...60 V c.a./c.c.

Codice Ordine: AF09Z400021 - Contattori fino a 100A-Contattori quadripolari AF09…AF38 a basso assorbimento-Poli 4 NA...

AF116-40-11-13 bob. 100...250 V c.a./c.c.
ABB

AF116401113

AF116-40-11-13 bob. 100...250 V c.a./c.c.

Codice Ordine: AF116401113 - Contattori oltre 100A-Contattori quadripolari AF09…AF370 e EK550..EK1000-160 A (AC-1 690 V)