The HF-ROL-range is used for forward and reverse running motors, as well as for switching non resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 500 V AC. The integrated electronic overload protection has a wide setting range that enables just three models to cover all requirements. Setting range of HF2.4-ROL-24VDC is 0.18 A to 2.4 A. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. ABB also offers a HF-ROLE safety range with emergency stop function. This offers Safety Integrity Level 3, in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1. The safety range is ATEX-certified.

Specifiche tecniche

Altezza 99 mm
Larghezza 22.5 mm
Profondità 114.5 mm
Con fusibile no
Con trasformatore no
Classe di intervento Classe 10 A
Assorbimento di potenza 3.3 W
Reset esterno possibile si
Tipo di avviatore motore Starter a inversione
Numero di punti di comando 16
Numero di segnalatori luminosi 4
Protocollo di supporto per ASI no
Supporta il protocollo per LON no
Corrente d'esercizio nominale Ie 2.4 A
Protocollo di supporto per TCP/IP no
Protocollo di supporto per SUCONET no
Tipo di tensione per l'azionamento DC
Protocollo di supporto per DeviceNet no
Montaggio su guida portante possibile si
Potenza nominale, 575 V, 60 Hz, 3 fase -
Supporta il protocollo per ethernet/IP no
Protocollo di supporto per Data-Highway no
Tipo coordinamento secondo IEC 60947-4-3 -
Potenza d'esercizio nominale per AC-3, 400 V 0.75 kW
Corrente d'esercizio nominale per AC-3, 400 V 2.4 A
Numero di contatti ausiliari, normalmente aperto 0
Tensione di alimentazione pilota nominale per DC 24 - 24 V
Tipo di collegamento circuito elettrico principale Raccordo a vite
Intervallo di regolazione sganciatore di sovraccarico 0.18 - 2.4 A
Tensione di alimentazione pilota nominale per AC 50 hz
Temperatura ambiente, limite superiore senza limitazione 80 °C
Corrente corto circuito nominale condizionale, coordinamento tipo 1, 480 Y/277 V -
Corrente di corto circuito nominale condizionale, coordinamento di tipo 2, 230 V -

Documenti

Deeplink REACH

1SAA983001-4501_en_C_REACh Info for Motor Controllers.pdf

Apri

Instructions for use

2CDC130013M0401.pdf

Apri

Declaration RoHS

1SVD981001-4401_ROHS_Electronic Relays and Controls_revB_DESTO_withAppendix.pdf

Apri

Prodotti correlati

Minicontattori VB6A 220 ... 240 V AC - 3 NO - 0 NC - Screw Terminals
ABB

EL 473 5

Minicontattori VB6A 220 ... 240 V AC - 3 NO - 0 NC - Screw Terminals

Codice Ordine: EL 473 5 - Minicontattori-Minicontattori invertitori tripolari con connessione a vite-4 kW (AC-3), bobina...

OT125F4C SEZIONATORE 4 POLI COMMUTATORE 125A
ABB

EE 243 0

OT125F4C SEZIONATORE 4 POLI COMMUTATORE 125A

Codice Ordine: EE 243 0 - La gamma di interruttori commutatori manuali ABB è disponibile per portate da 160 a 3200...

OT63F4C SEZIONATORE 4 POLI COMMUTATORE 63A
ABB

EE 229 9

OT63F4C SEZIONATORE 4 POLI COMMUTATORE 63A

Codice Ordine: EE 229 9 - La gamma di interruttori commutatori manuali ABB è disponibile per portate da 160 a 3200...

OTDC32F3 Sezionatore 3P 32 A 1000 V c.c.
ABB

OTDC32F3

OTDC32F3 Sezionatore 3P 32 A 1000 V c.c.

Codice Ordine: OTDC32F3 - La gamma di interruttori di manovra-sezionatori OTDC da 16 a 800 Ampere è stata progettata...

AF09Z-40-00-21 bob. 24...60 V c.a./c.c.
ABB

AF09Z400021

AF09Z-40-00-21 bob. 24...60 V c.a./c.c.

Codice Ordine: AF09Z400021 - Contattori fino a 100A-Contattori quadripolari AF09…AF38 a basso assorbimento-Poli 4 NA...

AF26-30-00-11 bob. 24...60 V c.a./c.c.
ABB

AF26300011

AF26-30-00-11 bob. 24...60 V c.a./c.c.

Codice Ordine: AF26300011 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-11 kW (AC-3...