HF2.4-ROLE 0,75 kW (AC-53) reg. 0,18…2,4 A alim. 24 V c.c.

Link copied
SKU
EAN
GTIN
MPN
The HF-ROLE-range is our safety range with emergency stop function. It's used for the direct-on-line start of motors and the switching of non-resistive loads. With contactor and overload relay functionalities integrated into one device, the results are faster wiring times and fewer faults. The range covers 0.6 A, 2.4 A and up to 9 A - for motors up to 3 kW – 500 V AC. The integrated electronic overload protection has a wide setting range that enables just three models to cover all requirements. Setting range of HF2.4-ROLE-24VDC is 0.18 A to 2.4 A. The control supply voltage is 24 V DC. For the control and main connection points ABB offers screw connections. Safety Integrity Level 3 in accordance with functional safety standard IEC 61508-1 and Performance Level 'e' in accordance with ISO 13849-1 are certified. Also ATEX is certified.

Specifiche tecniche

Altezza 99 mm
Larghezza 22.5 mm
Profondità 114.5 mm
Con fusibile no
Con trasformatore no
Classe di intervento Classe 10 A
Assorbimento di potenza 3.3 W
Reset esterno possibile si
Tipo di avviatore motore Starter a inversione
Numero di punti di comando 16
Numero di segnalatori luminosi 4
Protocollo di supporto per ASI no
Supporta il protocollo per LON no
Corrente d'esercizio nominale Ie 2.4 A
Protocollo di supporto per TCP/IP no
Protocollo di supporto per SUCONET no
Tipo di tensione per l'azionamento DC
Protocollo di supporto per DeviceNet no
Montaggio su guida portante possibile si
Potenza nominale, 575 V, 60 Hz, 3 fase -
Supporta il protocollo per ethernet/IP no
Protocollo di supporto per Data-Highway no
Tipo coordinamento secondo IEC 60947-4-3 -
Potenza d'esercizio nominale per AC-3, 400 V 0.75 kW
Corrente d'esercizio nominale per AC-3, 400 V 2.4 A
Numero di contatti ausiliari, normalmente aperto 0
Tensione di alimentazione pilota nominale per DC 24 - 24 V
Tipo di collegamento circuito elettrico principale Raccordo a vite
Intervallo di regolazione sganciatore di sovraccarico 0.18 - 2.4 A
Tensione di alimentazione pilota nominale per AC 50 hz
Temperatura ambiente, limite superiore senza limitazione 80 °C
Corrente corto circuito nominale condizionale, coordinamento tipo 1, 480 Y/277 V -
Corrente di corto circuito nominale condizionale, coordinamento di tipo 2, 230 V -

Documenti

Deeplink REACH

1SAA983001-4501_en_C_REACh Info for Motor Controllers.pdf

Apri

Instructions for use

2CDC130007M0401.pdf

Apri

Declaration RoHS

1SVD981001-4401_ROHS_Electronic Relays and Controls_revB_DESTO_withAppendix.pdf

Apri

Prodotti correlati

Minicontattori VB6A 220 ... 240 V AC - 3 NO - 0 NC - Screw Terminals
ABB

EL 473 5

Minicontattori VB6A 220 ... 240 V AC - 3 NO - 0 NC - Screw Terminals

Codice Ordine: EL 473 5 - Minicontattori-Minicontattori invertitori tripolari con connessione a vite-4 kW (AC-3), bobina...

OT125F4C SEZIONATORE 4 POLI COMMUTATORE 125A
ABB

EE 243 0

OT125F4C SEZIONATORE 4 POLI COMMUTATORE 125A

Codice Ordine: EE 243 0 - La gamma di interruttori commutatori manuali ABB è disponibile per portate da 160 a 3200...

OT63F4C SEZIONATORE 4 POLI COMMUTATORE 63A
ABB

EE 229 9

OT63F4C SEZIONATORE 4 POLI COMMUTATORE 63A

Codice Ordine: EE 229 9 - La gamma di interruttori commutatori manuali ABB è disponibile per portate da 160 a 3200...

OTDC32F3 Sezionatore 3P 32 A 1000 V c.c.
ABB

OTDC32F3

OTDC32F3 Sezionatore 3P 32 A 1000 V c.c.

Codice Ordine: OTDC32F3 - La gamma di interruttori di manovra-sezionatori OTDC da 16 a 800 Ampere è stata progettata...

AF09Z-40-00-21 bob. 24...60 V c.a./c.c.
ABB

AF09Z400021

AF09Z-40-00-21 bob. 24...60 V c.a./c.c.

Codice Ordine: AF09Z400021 - Contattori fino a 100A-Contattori quadripolari AF09…AF38 a basso assorbimento-Poli 4 NA...

AF26-30-00-11 bob. 24...60 V c.a./c.c.
ABB

AF26300011

AF26-30-00-11 bob. 24...60 V c.a./c.c.

Codice Ordine: AF26300011 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-11 kW (AC-3...