FCC/S1.2.2.1 CONTROL FANCOIL 0-10V 3V. M

Link copied
SKU
EAN
GTIN
MPN

FCC/S1.2.2.1 CONTROL FANCOIL 0-10V 3V. M di ABB è disponibile presso 1 grossista di materiale elettrico su Voltimum IT: MEF.

For the control of fan coil units. Via two analog outputs, two analog valves or one 6-way valve drive can be controlled for heating and cooling. For the fan control the devices features three relay outputs. A relay output switches an additional load of up to 16 A, such as auxiliary heating. Over 4 inputs the room status can be detected and monitored (Use for window contact, dew point sensor, level sensor or temperature sensor). Also it is possible to connect one analog room control unit (SAR/A or SAF/A) to the inputs of the device. The device has an integrated room temperature controller for the control of the room temperature, which can be used directly to control the outputs of the device. The FCC/S 1.2.2.1 features an easy to use manual operation. The device supports the ABB i-bus Tool for advanced diagnosis and improved commissioning.

Specifiche tecniche

Sistema bus LON no
Numero di uscite 5
Altri sistemi bus Senza
Numero moduli DIN 6
Sistema bus radio no
Tipo di montaggio Altro
Radio bidirezionale no
Sistema bus EIB/KNX si
Sistema bus Powernet no
Sistema bus radio KNX no
Grado di protezione (IP) IP20
Accoppiamento bus incluso si
Grandezza regolante costante si
Grandezza regolante commutante si
Max. corrente di commutazione (carico ohmico) -

Documenti

Deeplink REACH

9AKK108471A7754_en_B_Declaration regarding the REACH-Regulation.pdf

Apri

Dimensioned drawing

6_TE_MB_XX_V1-0_2CDC072026F0017_Rev_A.pdf

Apri

Instructions for use

FCCS 1.X.X.1_MBA_XX_V1-0_2CDG941188P0002.pdf

Apri

Declaration RoHS

9AKK108472A2583_en_A_RoHS Exemption Information.pdf

Apri

Declaration DOC CE (Declaration of conformity CE)

FCCS_1221_CE-ROHS_xx_V1-0_2CDK508224D2701.pdf

Apri

Prodotti correlati

FCC/S1.2.1.1 CONTROL FANCOIL 0-10V 3VEL
ABB

2CDG110212R0011

FCC/S1.2.1.1 CONTROL FANCOIL 0-10V 3VEL

For the control of fan coil units. Via two analog outputs, two analog valves or one 6-way valve drive can be...

FCC/S1.3.2.1 CONTR FANCOIL 0-10V 0-10V M
ABB

2CDG110215R0011

FCC/S1.3.2.1 CONTR FANCOIL 0-10V 0-10V M

For the control of fan coil units. Via two analog outputs, two analog valves or one 6-way valve drive can be...

FCC/S1.3.1.1 CONTROL FANCOIL 0-10V 0-10V
ABB

2CDG110214R0011

FCC/S1.3.1.1 CONTROL FANCOIL 0-10V 0-10V

For the control of fan coil units. Via two analog outputs, two analog valves or one 6-way valve drive can be...

FCC/S1.1.2.1 CONTROL FANCOIL PWM 3VEL M
ABB

2CDG110211R0011

FCC/S1.1.2.1 CONTROL FANCOIL PWM 3VEL M

For the control of fan coil units. Via two electronic outputs, two thermoelectric or one motor-driven valve drive can be...

HCC/S2.1.2.1 CONTROL HVAC 0-10V 2VIE M.
ABB

2CDG110219R0011

HCC/S2.1.2.1 CONTROL HVAC 0-10V 2VIE M.

For the control of a heating or cooling circuit. The device has 2 channels, each with an analog output to control the...

VC/S4.2.1 CONTROLLORE VALVOLE 4 VIE MAN.
ABB

2CDG110217R0011

VC/S4.2.1 CONTROLLORE VALVOLE 4 VIE MAN.

For the control of heating and cooling applications in the room, such as radiator, floor heating or cooling ceiling. The...