Vai al contenuto
KNX Presence Mini Pre W

KNX Presence Mini Pre W

Detection range (for mounting height 2.5 m, 3 m and 4 m): circular. Seated persons Ø: max. 5 m, max. 6.5 m and max. 9 m. Walking persons Ø: max. 6.5 m, max. 8 m and max. 10.5 m. Visible height 16 mm. With 4 channels. For dimming/brightness of the rules to a defined value in a designated collection area. HVAC function for controlling heating and/or cooling systems and ventilation systems in the designated collection area. Detectors application with 2 power off stages. Detectors application with integrated monitoring function. Constant light controller with up to two independent channels. Constant light controller with max. 2 outputs for dimming daylight control/rules of two rooflights in the room. Integrated object room temperature controller. 10 freely programmable IR channels (blue and/or white) Incl. 5 logic channels (logic gates, gates, delay and staircase lighting) Evaluation via internal brightness sensor. Weighting of up to 2 external brightness values ​​and the internal brightness sensor possible. The programming button can be activated with the IR transmitter 6010-25 (-500). With integrated KNX bus coupler. Suitable for false ceilings with a board thickness from 9 to 25 mm. Hole size: Ø 68 mm. Suitable for surface mounting installation. Cannot be installed in British Standard or VDE flushmounted box. Recommendation: Installation housing from Installation housing from Kaiser HaloX-O (Art.no. 1281-00) with corresponding cover plates (1281-xx for fair faced concrete) or IBTronic H120-68 from Spelsberg.

Codici prodotto

SKU: KNXH0048
EAN: 4011395185919
GTIN: 4011395185919
MPN: 6131/21-183-500

Specifiche tecniche

Colore Alluminio
Altezza 80 mm
Diametro -
Larghezza 80 mm
Materiale Plastica
Tipologia Segnalatore di presenza
Profondità 45 mm
Trasparente no
Tipo superficie Opaco
Altri sistemi bus Senza
Tipo di montaggio A parete
Codice RAL (simile) 9006
Sistema bus EIB/KNX si
Sistema bus Powernet no
Larghezza di montaggio -
Profondità di incasso 29 mm
Potenza di interruzione -
Accoppiamento bus incluso si
Alimentazione elettrica bus -
Durata di funzionamento max. 1092 min
Ingresso stazione secondaria si
Altezza di montaggio ottimale 2 m
Angolo di rilevamento verticale
Diametro foro montaggio ad incasso -
Lunghezza del cavo di collegamento -
Max. portata trasmissione laterale 8 m
Controllore Illuminazione vano scale si
Commutatore del modo di funzionamento no
Funzione teach per luminosità di intervento si
Ritardo di disinserzione con apprendimento automatico no