The softstarter PSTX250-690-70 has a rated maximum operational current of 250 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.To interact with PSTX, it has a detachable full graphic display with IP66 and 4x outdoor rating. There are four ways to communicate with PSTX. It can be done by hardwire inputs Start/Stop/Reset of fault, and by three programmable digital inputs. Another popular option is the built-in Fieldbus communication Modbus RTU and incl optional ANYBUS modules with every major protocol such as for example Profinet, Profibus, Modbus TCP, Ethernet IP and others. Another way to communicate with PSTX is to use an external adaptor and a Fieldbus plug. PSTX is the complete alternative for any motor starting application. It’s suitable for medium to large-sized three-phase motors with nominal currents from 30...1250 A inline connection or 52...2160 A inside delta connection. Typical applications are, for example, pumps, fans, compressors, and conveyors.

Specifiche tecniche

Funzione -
Con display si
Classe di intervento Regolabile
Cavallottamento interno si
Grado di protezione (IP) IP00
Regolazione della coppia si
Grado di protezione (NEMA) 1
Tensione d'esercizio nominale Ue 208 - 690 V
Corrente d'esercizio nominale Ie a 40°C Tu 250 A
Tensione di alimentazione pilota nominale per DC
Tensione di alimentazione pilota nominale per AC 50 hz 100 - 250 V
Potenza nominale motore trifase, circuito standard, a 230 V 75 kW
Potenza nominale motore trifase, circuito a radice di 3, a 230 V 132 kW

Documenti

Deeplink REACH

2CMT2022-006481_en_D_REACh Declaration for all Softstarters.pdf

Apri

Instructions for use

1SFC132428M0201_A_A_2 (1).pdf

Apri

Declaration RoHS

2CMT2022-006500_en_C_RoHS II Declaration for all Softstarters.pdf

Apri

Prodotti correlati

AF09-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA
ABB

AF09301013

AF09-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA

Codice Ordine: AF09301013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-4 kW (AC-3...

AF116-40-11-13 bob. 100...250 V c.a./c.c.
ABB

AF116401113

AF116-40-11-13 bob. 100...250 V c.a./c.c.

Codice Ordine: AF116401113 - Contattori oltre 100A-Contattori quadripolari AF09…AF370 e EK550..EK1000-160 A (AC-1 690 V)

AF12-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA
ABB

AF12301013

AF12-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA

Codice Ordine: AF12301013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-5,5 kW...

AF16-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA
ABB

AF16301013

AF16-30-10-13 bob. 100...250 V c.a./c.c., aux 1NA

Codice Ordine: AF16301013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-7,5 kW...

AF205-40-11-13 bob. 100...250 V c.a./c.c.
ABB

AF205401113

AF205-40-11-13 bob. 100...250 V c.a./c.c.

Codice Ordine: AF205401113 - Contattori oltre 100A-Contattori quadripolari AF09…AF370 e EK550..EK1000-350 A (AC-1 690 V)

AF26-30-00-13 bob. 100...250 V c.a./c.c.
ABB

AF26300013

AF26-30-00-13 bob. 100...250 V c.a./c.c.

Codice Ordine: AF26300013 - Contattori fino a 100A-Contattori tripolari AF09…AF2650 con bobina c.a. e c.c.-11 kW (AC-3...